Walker Home PageSite Map
Contact Us

 

 
Advanced Search

Click here for Income Tax Forms

Departments Section
Services IndexAssessorBuilding DepartmentCity ClerkCity Manager
District CourtEngineeringFinanceFire DepartmentWalker Ice and Fitness Center
Income TaxLibraryParks and RecreationPoliceProbationPublic WorksTreasurer

Community Development
Overview  |  Building Permit and Inspection Services  |  Zoning Administration Services
Community Planning Services
 
Community Development > Community Planning Services
Overview  |  Planning Commission Information and Activity Reports  |  Master Plan Information
Maps, Special Studies and Reports  |  City Ordinances  |  Site Plans  |  This document is available to view in PDF format. Oil Wells and Water Wells
REGIS Mapping Service  |  This document is available to view in PDF format. Timeline Planning Issues Article  |  Forestry Issues
Community Planning Website Links  |  FAQ's  |  Forms
 
 
Community Development > Community Planning Services > Planning Commission Information and Activity Reports
This document is available to view in PDF format. Planning Commission Application  |  Fee Schedule  |  Meeting and Application Deadlines
Site Plan Review Checklist  |  DPW Staking Note  |  Escrow Policy
Post Site Plan Approval Checklist  |  Planning Commission Minutes and Agendas
Planning and Zoning Process  |  2011 Yearly Report  |  2010 Yearly Report  |  2009 Yearly Report
2008 Yearly Report  |  2007 Yearly Report  |  2006 Yearly Report  |  2005 Yearly Report
2004 Yearly Report

Site Plan Review Checklist

All site plans shall contain the following information so the Planning Commission can adequately review the proposed use or activity. The type or level of information may vary depending upon the scale, scope, or nature of the request. The information shall be presented in sufficient detail to describe adequate dimensions to show the size and placement of all proposed structures, and adequate contour elevations to determine the existing and proposed configuration of the site for engineering purposes. The information shall also be provided in sufficient detail to determine the demand on the capacities of public services and facilities.

This documnet is available in PDF format. To view the checklist now, click here

Required Site Plan Information

___ An accurate site plan drawn to a scale not larger than 1" = 100 feet.

___ Property boundaries, property dimensions (including width, length, acreage, and frontage).

___ North arrow.

___ A project description.

___ Existing zoning of the property and zoning of all adjacent properties within 300 feet.

___ The location, size, height (shown on a building elevation), and use (including floorplan) of all existing and proposed buildings, structures, or man-made features.

___ Proposed setbacks, lot lines, typical layout, and distances between structures and between structures and lot lines.

___ The dimensions and number of proposed lots.

___ The location, surface width, and right-of-way width, as applicable, public rights-of-way, streets, drives, alleys, easements (including utility), acceleration and deceleration lanes, pedestrian walkways, and loading areas, including relationship to existing rights-of-way.

___ Any existing or proposed private streets.

___ The location, number, and size of parking spaces as specified by the Zoning Ordinance. Parking spaces shall be designated by lines showing individual spaces.

___ The location and specifications of exterior lighting.

___ The location of all existing and proposed landscaping and vegetation, including number of trees and shrubs by species and caliper.

___ All known natural resources or natural features to be preserved.

___ The location, height and type of existing and proposed fences, walls, retaining walls, screening, berms and buffer zones.

___ The location of dumpsters, waste disposal areas, and loading facilities.

___ The location and size of existing and proposed hydrants and utilities, including proposed connections to public sewer and water supply systems.

___ The location and size of all surface and subsurface water drainage facilities, and county and/or local drainage ways, existing and proposed, with flow and runoff calculations.

___ The location of any floodplain areas, bodies of water, wetlands, or other unbuildable areas.

___ The location and size of all signs in accordance with the Zoning Ordinance.

___ The approximate locations of all buildings, structures and driveways on properties within 100 feet of any lot line of the subject properties.

___ The location, size and purpose of any proposed open spaces or recreational areas.

___ Driveway / access specifications.

___ Locations of existing or proposed above or below ground storage facilities, and any containment structures, for chemicals, flammable materials, or hazardous materials.

___ For residential developments, density calculations, number and types of residential units, and floor area per habitable space.

___ The square footage that will be devoted to nonresidential purposes, and the number of rooms in hotels or motels.

___ A topographic map showing present and proposed elevations at contour levels or not more than five feet, and showing the relationship of the topography of the land to adjoining land.

___ Where excavation, fill or recontouring of the site is involved, proposed grading and final contours shall be shown.

Required Narrative

A narrative shall be provided (either on the site plan or submitted separately) which contains the following information:

___ The owner and applicant’s name and address.

___ The name, address and phone number of the individual who prepared the plan, and the date of preparation.

___ The common description and complete legal description of the property.

___ The approximate number of acres allocated to each proposed use and gross area in building, structures, parking, public and/or private streets and drives, and open space.

___ Dwelling unit densities by type, if applicable.

___ A development and construction schedule indicating the intended date(s) for commencement of construction of all or portions or phases of the project.

___ Deed restrictions or other covenants affecting the land.

___ Proposed method of providing sewer and water service, as well as other public and private utilities.

___ Proposed method of providing storm drainage.

___ Permits and/or approvals required by state, federal, county, or other local agencies.

Other Information

Any additional information that is deemed by the Planning Commission to be reasonably necessary to adequately evaluate the proposed use or activity and its effects on the City, including, without limitation, additional studies (e.g. traffic impact analysis, impacts on natural features and drainage, soil tests), graphics (e.g. aerial photography), or written materials.

2010 Meeting Schedule

January 14
January 28
February 11
February 25
March 11
March 25
April 15
April 29
May 13
May 27
June 10
June 24
July 15
July 29

August 12
August 26
September 9
September 23
October 14
October 28
November 11
November 25
December 9
December 23 (cancelled)

All meetings are scheduled to begin at 9:00am in the DPW Conference Room unless otherwise noted.

 

Back To Top

 

 

 

Government  |  Departments  |  Community  |  Resource Center
Contact Us  |  Search  |  Site Map  |  Home  |  
Site Use Policy

Bringing the World to Your Corner of the WorldThe City of Walker, Michigan
4243 Remembrance Rd. NW
Walker, MI  49534
(616)453-6311
City Hall hours: Mon-Thursday from 7:30am to 5:30pm. Closed Fridays
All information © 2012 City of Walker

Contact Us!
If you would like to leave general comments about the website, click here.
Click here to report technical problems with the website.